Educational hydrate operating-margin screening placeholder with public assumptions. USE WHEN: a task needs a quick check of whether an operating point keeps a safe temperature margin above a hydrate equilibrium temperature and should be directed to validated NeqSim methods for real calculations.
Educational hydrate risk screening placeholder with public assumptions. USE WHEN: a task needs a quick hydrate risk triage and should be directed to validated NeqSim methods for real calculations.
Educational multiphase slug-flow regime and slug-catcher volume screening. USE WHEN: a task needs a public, screening-level indicator of whether a multiphase line is in an intermittent/slug regime and a first-pass slug-catcher volume estimate before validated multiphase flow analysis.
Run the OLGA transient multiphase flow simulator from Python: locate the installation, generate its PVT table and hydrate equilibrium curve from a NeqSim fluid, validate a genkey case with a rule check, launch the batch engine with the right flags, decode the engine exit code, and read .tpl trend and .ppl profile…
Public produced-water brine builder and screening-level scale evaluation. USE WHEN: a task needs to turn an ion analysis, preset, or TDS value into a NeqSim-ready electrolyte ion mapping and a quick scale/mixing-incompatibility screening (BaSO4, SrSO4, CaSO4, CaCO3), and should be directed to validated NeqSim…
Educational SURF flowline/riser cooldown and no-touch-time screening placeholder with public assumptions. USE WHEN: a task needs a quick, public estimate of how long an insulated subsea flowline stays above its hydrate formation temperature after shutdown, and should be directed to validated NeqSim methods for real…
Educational two-phase flow-regime screening that classifies a horizontal gas-liquid flow pattern from superficial velocities using a simplified public Mandhane-style map and flags slug risk. USE WHEN: a task needs a public, screening-level flow-regime flag (stratified, slug, annular, bubble) and slug-risk triage to…
Educational wax operating-margin screening placeholder with public assumptions. USE WHEN: a task needs a quick check of whether an operating point keeps a safe temperature margin above a wax appearance temperature and should be directed to validated NeqSim methods for real calculations.
Educational acoustic-induced-vibration (AIV) screening using the public Energy Institute likelihood-of-failure form for gas pressure-reducing devices. USE WHEN: a task needs a public, screening-level estimate of sound power level, pipe diameter-to-thickness ratio, allowable sound power level, and an AIV…
Link a NeqSim process simulation and engineering documents to a CFD study, single-phase or multiphase. Merges P&ID, STID, datasheet and plant-data inputs into a traceable design basis, converts a flashed NeqSim fluid into CFD boundary conditions, takes both phases and the interfacial tension from a multiphase flash…
Set up anti-surge recycle control for a centrifugal compressor in NeqSim, including compressor-chart generation, steady-state AntiSurgeRecycleCalculator use, dynamic AntiSurgeController PI control, and CompressorAntiSurgeApplication topology binding for hot/cold recycle valves and speed runback. USE WHEN: a task needs…
Educational compressor operating window screening against surge and stonewall margins. USE WHEN: a task needs a public, screening-level check that a centrifugal compressor operating point sits inside the surge and stonewall limits before detailed performance review.
Educational centrifugal-compressor power screening using the public polytropic-head equation (API 617 / API 619 style). USE WHEN: a task needs a public, screening-level estimate of polytropic head, discharge temperature, and gas power for a single compression stage before detailed compressor selection.
Educational control-valve sizing screening that estimates the required flow coefficient (Kv/Cv) and flags choked flow per public IEC 60534-2-1 / ISA-75.01 equations for liquid and gas service. USE WHEN: a task needs a public, screening-level required Cv and a choked-flow flag before detailed control-valve selection.
Educational dry gas seal supply and condensation screening for centrifugal compressors. USE WHEN: a task needs a public, screening-level estimate of seal-gas and separation-gas supply demand and a seal-gas condensation-margin check (cavity temperature versus hydrocarbon dew point) before detailed dry gas seal system…
Set up measurement devices and PID-style controllers for NeqSim dynamic process simulations. USE WHEN: a task needs to add transmitters, controller devices, valve manipulation, setpoints, controller action, and autotuning workflow guidance before runTransient calculations.
Prepare NeqSim ProcessSystem and ProcessModel flowsheets for dynamic simulation, including equipment holdup, mechanical-design, and volume-readiness checks. USE WHEN: a task needs to convert a steady-state NeqSim process into a dynamic-ready model before runTransient calculations.
Link a NeqSim process simulation and engineering documents to a finite-element model of the solid: heat conduction through a layered wall, transient cooldown, species diffusion in porous rock, and the thermal and pressure stress that follow. Merges P&ID, STID, datasheet, insulation-specification and inspection inputs…
Educational fired-heater duty and radiant-flux screening using public energy-balance relations (API 560 style). USE WHEN: a task needs a public, screening-level estimate of process duty, fired duty, fuel rate, and average radiant flux for a fired heater before detailed thermal design.
Educational flow-induced vibration (FIV) screening using a public fluid kinetic-energy (rho v^2) likelihood-of-failure index. USE WHEN: a task needs a public, screening-level check of whether a main-line flow velocity and density produce a kinetic-energy level that warrants a detailed Energy Institute style FIV…
Educational gas-scrubber sizing screening using the public Souders-Brown / K-factor relation for vertical separators with a mist-eliminator gas-load check. USE WHEN: a task needs a public, screening-level estimate of the Souders-Brown velocity, required vessel diameter, velocity utilisation, and mist-eliminator load…
Educational gas-turbine performance screening using open ISO 3977 / GL1029 style derate factors. USE WHEN: a task needs a public, screening-level estimate of site-rated shaft power, site heat rate, thermal efficiency, fuel heat input, exhaust mass flow, and exhaust temperature for a gas-turbine driver before detailed…
Educational process line velocity screening against erosional velocity and recommended velocity guidelines. USE WHEN: a task needs a public, screening-level check that a pipe or line operates within erosional and recommended velocity limits before detailed line sizing.
Standards-based gas-valve and restriction noise screening at a stated receiver distance using either a current measured A-weighted level or a conservative pressure-drop energy model. USE WHEN: a task needs noise triage, receiver/workplace assessment, or routing to detailed IEC 60534-8-3 prediction while keeping…